First Alert Photoelectric Smoke Alarm With Escape Light Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Détecteurs de fumée First Alert Photoelectric Smoke Alarm With Escape Light. First Alert Photoelectric Smoke Alarm With Escape Light User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
I
MPORTANT!
P
LEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Smoke
Alarm’s operation. If you are installing this Smoke Alarm for use by
others, you must leave this manual—or a copy of it—with the end user.
USER’S MANUAL
P
rinted in Mexico
M
08-0136-007 K1 12/12
INTRODUCTION
Thank you for choosing First Alert
®
for your Smoke Alarm needs. You
have purchased a state of the art Smoke Alarm designed to provide you
with early warning of a fire. Please take the time to read this manual and
make the Smoke Alarm an integral part of your family’s safety plan.
K
ey Features of the SA720 Smoke Alarm:
Photoelectric Sensing Technology: Photoelectric Sensors are generally
more sensitive than ionization sensors in detecting smoldering fires
which commonly occur in couches or bedding.
OptiPath 360 Technology™: Patented technology provides 360° of
direct access to the smoke sensor.
S
ingle Test/Silence Button: Allows you to test the alarm or silence
n
uisance alarms. Testing the Alarm assures you that the unit is functioning
c
orrectly and ready to protect you and your family. The Alarm can be
s
ilenced for up to 15 minutes in the event of a nuisance alarm.
A
larm Latch: Remembers which unit initiated an alarm.
Escape Light
®
: Bright escape light activates when this unit goes into
alarm to illuminate your path to safety.
B
attery Drawer with “battery missing” lockout: Allows you to easily
r
eplace the battery with out removing the alarm from the ceiling.
T
he battery door will not close if a battery has not been inserted thus
a
lerting you that the unit is not powered and not operating.
L
ow battery warning: The Alarm will sound a “chirp” once per minute
w
hen the battery needs to be replaced.
B
linking Power Indicator: Confirms that the Smoke Alarm is receiving
p
ower.
©
2012 BRK Brands, Inc. All rights reserved.
D
istributed by BRK Brands, Inc.
3
901 Liberty Street Road, Aurora, IL 60504-8122
C
onsumer Affairs: (800) 323-9005 www.firstalert.com
FIRE SAFETY TIPS
F
ollow safety rules and prevent hazardous situations: 1) Use smoking
m
aterials properly. Never smoke in bed. 2) Keep matches or lighters
a
way from children; 3) Store flammable materials in proper containers;
4
) Keep electrical appliances in good condition and don’t overload elec-
t
rical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
g
rease- and debris-free; 6) Never leave anything cooking on the stove
u
nattended; 7) Keep portable heaters and open flames, like candles,
a
way from flammable materials; 8) Don’t let rubbish accumulate.
K
eep alarms clean, and test them weekly. Replace alarms immediately
i
f they are not working properly. Smoke Alarms that do not work cannot
a
lert you to a fire. Keep at least one working fire extinguisher on every
f
loor, and an additional one in the kitchen. Have fire escape ladders or
o
ther reliable means of escape from an upper floor in case stairs are
b
locked.
BEFORE YOU INSTALL THIS SMOKE ALARM
Important! Read “Recommended Locations for Smoke Alarms” and
“Locations to Avoid for Smoke Alarms” before beginning. This unit
monitors the air, and when smoke reaches its sensing chamber,
it alarms. It can give you more time to escape before fire spreads.
This unit can ONLY give an early warning of developing fires if it is
installed, maintained and located where smoke can reach it, and where
all residents can hear it, as described in this manual. This unit will not
sense gas, heat, or flame. It cannot prevent or extinguish fires.
Understand The Different Type of Smoke Alarms
Battery powered or electrical? Different Smoke Alarms provide
different types of protection. See “About Smoke Alarms” for details.
Know Where To Install Your Smoke Alarms
Fire Safety Professionals recommend at least one Smoke Alarm on
every level of your home, in every bedroom, and in every bedroom
hallway or separate sleeping area. See “Recommended Locations
For Smoke Alarms” and “Locations To Avoid For Smoke Alarms” for
details.
Know What Smoke Alarms Can and Can’t Do
A Smoke Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once smoke reaches the sensor.
See “Limitations of Smoke Alarms” for details.
Check Your Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family
home. It alone will not meet requirements for boarding houses,
apartment buildings, hotels or motels. See “Special Compliance
Considerations” for details.
HOW TO INSTALL THIS SMOKE ALARM
THE PARTS OF THIS SMOKE ALARM
FOLLOW THESE SIMPLE STEPS!
*
All First Alert
®
S
moke Alarms conform to regulatory requirements,
i
ncluding UL217 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.
I
onization technology is generally more sensitive than photoelectric
t
echnology at detecting small particles, which tend to be produced
i
n greater amounts by flaming fires, which consume combustible
m
aterials rapidly and spread quickly. Sources of these fires may include
p
aper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be produced
in greater amounts by smoldering fires, which may smolder for
hours before bursting into flame. Sources of these fires may include
cigarettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each
level and in every bedroom of your home.
This unit will not alert hearing impaired residents. It is recom-
mended that you install special units which use devices like
flashing strobe lights to alert hearing impaired residents.
Do not connect this unit to any other alarm or auxiliary
device. It is a single-station unit that cannot be linked to other
devices. Connecting anything else to this unit may prevent it
from working properly.
Unit will not operate without battery power. The Smoke Alarm
cannot work until you install the battery in the correct position
(Match “+” to “+” and “-” to “-”).
This Smoke Alarm has a battery drawer which resists closing
unless a battery is installed.
Do not install this unit over an electrical junction box.
Air currents around junction boxes can prevent smoke from
reaching the sensing chamber and prevent the unit from
alarming. Only AC powered units are intended for installation
over junction boxes.
Do not stand too close to the unit when the alarm is sounding.
It is loud to wake you in an emergency. Exposure to the horn
at close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to the
sensing chamber and prevent the unit from operating properly.
1 2 3
1. Mounting bracket
2
. Mounting slots
3
. Battery drawer, install 9V
b
attery here
4
. Turn this way to remove
f
rom bracket
5. Turn this way to attach
to bracket
1
. Test/Silence button
2. Battery drawer
3
. Power indicator light and
a
larm indicator
4. Escape Light
®
If you want to lock the battery drawer, or lock the Smoke Alarm
to the mounting bracket, please read the “Optional Locking
Features” section before you begin installation.
1. Hold base firmly and twist the mounting bracket counterclockwise
to separate it from the base.
2. Hold the mounting bracket against the ceiling (or wall) so the
vertical mounting slot is aligned in the 12 o’clock position and
trace around the inside of the mounting slots (vertical and
horizontal mounting).
3. Put the unit where it won’t get covered with dust when you drill
the mounting holes.
4. Using a 3/16” (5 mm) drill bit, drill a hole through the center of the
oval outlines you traced.
5. Insert the plastic screw anchors (in the plastic bag with screws)
into the holes. Tap the screw anchors gently with a hammer, if
necessary, until they are flush with the ceiling or wall.
6
. Attach the mounting bracket to the ceiling or wall.
7
. Install the battery (included). Open the
b
attery drawer. Match the terminals on the
e
nd of the battery with the terminals on the
u
nit. Match “+” to “+” and “-” to “-.” Push
t
he battery in until it snaps in securely and
c
annot be shaken loose. If the battery is
n
ot snapped in completely, the unit cannot
r
eceive battery power.
NOTE: After you install the battery, the power indicator light
may flash. (If the unit alarms, the light will blink rapidly, and the
horn will repeatedly sound 3 beeps, pause, 3 beeps.)
8
. Attach the Smoke Alarm to the mounting bracket. Line up the
g
uides on the alarm’s base with the guides on the mounting
b
racket. When guides are lined up, turn the base clockwise (right)
until it snaps into place.
NOTE: Once the Smoke Alarm is snapped onto the mounting
bracket, you can rotate the Smoke Alarm to adjust the align-
ment.
9
. Test the Smoke Alarm. See “Weekly Testing.”
I
F THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
During an alarm, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause. The Escape Light
®
will turn on.
LED flashes once every second.
If the unit alarms get everyone out of the house immediately.
If the unit alarms and you are not testing the unit, it is warning
you of a potentially dangerous situation that requires your
immediate attention. NEVER ignore any alarm. Ignoring the
alarm may result in injury or death.
Never remove the batteries from a battery operated Smoke Alarm
t
o stop an unwanted alarm (caused by cooking smoke, etc.).
R
emoving batteries disables the alarm so it cannot sense smoke,
a
nd removes your protection. Instead open a window or fan the
s
moke away from the unit. The alarm will reset automatically.
IF YOU SUSPECT A PROBLEM
S
moke Alarms may not operate properly because of dead, missing or
w
eak batteries, a build-up of dirt, dust or grease on the Smoke Alarm
c
over, or installation in an improper location. Clean the Smoke Alarm as
d
escribed in “Regular Maintenance,” and install a fresh battery, then test
t
he Smoke Alarm again. If it fails to test properly when you use the test
b
utton, or if the problem persists, replace the Smoke Alarm immediately.
If you hear a “chirp” about once a minute, replace the battery.
If you hear 3 “chirps” approximately once a minute, replace the
alarm immediately. This is the malfunction indicator.
If you experience frequent non-emergency alarms (like those
c
aused by cooking smoke), try relocating the Smoke Alarm.
If the alarm sounds when no smoke is visible, try cleaning or
relocating the Smoke Alarm. The cover may be dirty.
If the alarm does not sound during testing, try installing a new
battery, and make sure it is snapped in securely.
The Escape Light
®
b
ulb is not replaceable. In the unlikely event
t
hat the Escape Light
®
d
oes not operate during testing, please
o
btain warranty service.
If the Smoke Alarm is still not operating properly, and it is still under
warranty, please see “How to Obtain Warranty Service” in the Limited
Warranty.
D
o not try fixing the alarm yourself – this will void your warranty!
SMOKE AND FIRE* ALARM
LIMITED WARRANTY
BRK Brands, Inc., ("BRK") the maker of First Alert
®
brand products
warrants that for a period of ten years from the date of purchase, this
product will be free from defects in material and workmanship. BRK, at
its option, will repair or replace this product or any component of the
product found to be defective during the warranty period. Replacement
will be made with a new or remanufactured product or component.
If the product is no longer available, replacement may be made with a
similar product of equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of
initial retail purchase and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain warranty performance.
BRK dealers, service centers, or retail stores selling BRK products do
not have the right to alter, modify or any way change the terms and
conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting
from any of the following: negligent use or misuse of the product, use on
improper voltage or current, use contrary to the operating instructions,
disassembly, repair or alteration by anyone other than BRK or an
authorized service center. Further, the warranty does not cover Acts of
God, such as fire, flood, hurricanes and tornadoes or any batteries that
are included with this unit.
BRK shall not be liable for any incidental or consequential damages
caused by the breach of any express or implied warranty. Except to
the extent prohibited by applicable law, any implied warranty of
merchantability or fitness for a particular purpose is limited in duration
to the duration of the above warranty. Some states, provinces or
jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty
lasts, so the above limitations or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other
rights that vary from state to state or province to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your retailer.
In order to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time,
Monday through Friday. To assist us in serving you, please have the
model number and date of purchase available when calling.
For Warranty Service return to: 25 Spur Drive, El Paso, TX 79906
Battery: BRK Brands, Inc. make no warranty, express or implied, written
or oral, including that of merchantability or fitness for any particular
purpose with respect to battery.
RECOMMENDED LOCATIONS FOR
S
MOKE ALARMS
Installing Smoke Alarms in Single-Family Residences
The National Fire Protection Association (NFPA), recommends one
Smoke Alarm on every floor, in every sleeping area, and in every bed-
room. In new construction, the Smoke Alarms must be AC powered and
interconnected. See “Agency Placement Recommendations” for details.
For additional coverage, it is recommended that you install a Smoke
Alarm in all rooms, halls, storage areas, finished attics, and basements,
where temperatures normally remain between 40˚ F (4.4˚ C) and 100˚ F
(37.8˚ C). Make sure no door or other obstruction could keep smoke
from reaching the Smoke Alarms.
More specifically, install Smoke Alarms:
O
n every level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with doors closed.
In the hall near every sleeping area. If your home has multiple
sleeping areas, install a unit in each. If a hall is over 40 feet (12
meters) long, install an alarm at each end.
At the top of the first-to-second floor stairway, and at bottom of
b
asement stairway.
Specific requirements for Smoke Alarm installation vary from state to
state and from region to region. Check with your local Fire Department
for current requirements in your area. It is recommended AC or AC/DC
units be interconnected for added protection.
AGENCY PLACEMENT RECOMMENDATIONS
NFPA 72 Chapter 29
For your information, the National Fire Alarm and Signaling Code,
N
FPA 72, reads as follows:”
2
9.5.1* Required Detection.
29.5.1.1* Where required by other governing laws, codes, or standards
for a specific type of occupancy, approved single and multiple-station
smoke alarms shall be installed as follows:
(1)*In all sleeping rooms and guest rooms
(
2)*Outside of each separate dwelling unit sleeping area, within 21 ft
(
6.4 m) of any door to a sleeping room, with the distance measured
a
long a path of travel
(
3) On every level of a dwelling unit, including basements
(4) On every level of a residential board and care occupancy (small
facility), including basements and excluding crawl spaces and
unfinished attics
(5)*In the living area(s) of a guest suite
(
6) In the living area(s) of a residential board and care occupancy
(
small facility)
(
Reprinted with permission from NFPA 72
®
,
National Fire Alarm and
S
ignaling Code Copyright © 2010 National Fire Protection Association,
Q
uincy, MA 02269. This reprinted material is not the complete and
o
fficial position of the National Fire Protection Association, on the
r
eferenced subject which is represented only by the standard in its
e
ntirety), (National Fire Alarm and Signaling Code
®
a
nd NFPA 72
®
a
re
r
egistered trademarks of the National Fire Protection Association, Inc.,
Q
uincy, MA 02269).
C
alifornia State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire
detection equipment in all rooms and areas of the household as follows:
A Smoke Alarm installed in each separate sleeping area (in the vicinity,
but outside bedrooms), and Heat or Smoke Alarms in the living rooms,
dining rooms, bedrooms, kitchens, hallways, finished attics, furnace
rooms, closets, utility and storage rooms, basements, and attached
garages.
LOCATIONS TO AVOID FOR SMOKE ALARMS
For best performance, it is recommended you AVOID installing
Smoke Alarms in these areas:
Where combustion particles are produced. Combustion particles
form when something burns. Areas to avoid include poorly ventilated
kitchens, garages, and furnace rooms. Keep units at least 20 feet
(6 meters) from the sources of combustion particles (stove, furnace,
water heater, space heater) if possible. In areas where a 20-foot
(6-meter) distance is not possible – in modular, mobile, or smaller
homes, for example – it is recommended the Smoke Alarm be
placed as far from these fuel-burning sources as possible. The
placement recommendations are intended to keep these Alarms at
a reasonable distance from a fuel-burning source, and thus reduce
“unwanted” alarms. Unwanted alarms can occur if a Smoke Alarm
is placed directly next to a fuel-burning source. Ventilate these
areas as much as possible.
In air streams near kitchens. Air currents can draw cooking smoke
into the sensing chamber of a Smoke Alarm near the kitchen.
In very damp, humid or steamy areas, or directly near bathrooms
with showers. Keep units at least 10 feet (3 meters) away from
showers, saunas, dishwashers, etc.
Where the temperatures are regularly below 40˚ F (4.4˚ C) or above
100˚ F (37.8˚ C), including unheated buildings, outdoor rooms,
porches, or unfinished attics or basements.
In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm
directly over the stove or range. Keep laundry room Smoke Alarms
free of dust or lint.
Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can
blow smoke away from the unit, preventing it from reaching the
sensing chamber.
In insect infested areas. Insects can clog openings to the sensing
chamber and cause unwanted alarms.
Less than 12 inches (305mm) away from fluorescent lights.
Electrical “noise” can interfere with the sensor.
In “dead air” spaces. “Dead air” spaces may prevent smoke from
reaching the Smoke Alarm.
Avoiding Dead Air Spaces
“Dead air” spaces may prevent smoke from reaching the Smoke Alarm.
To avoid dead air spaces, follow the installation recommendations
below.
On ceilings, install Smoke Alarms as close to the center of the ceiling
as possible. If this is not possible, install the Smoke Alarm at least 4
inches (102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of
Smoke Alarms should be placed between 4 and 12 inches (102 and
305 mm) from the wall/ceiling line, below typical “dead air” spaces.
On a peaked, gabled, or cathedral ceiling, install the first Smoke
Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured
horizontally. Additional Smoke Alarms may be required depending on
the length, angle, etc. of the ceiling's slope. Refer to NFPA 72 for
details on requirements for sloped or peaked ceilings.
SPECIAL COMPLIANCE CONSIDERATIONS
T
his Smoke Alarm is suitable for use in apartments, condominiums,
t
ownhouses, hospitals, day care facilities, health care facilities, boarding
h
ouses, group homes and dormitories provided a primary fire detection
s
ystem already exists to meet fire detection requirements in common
a
reas like lobbies, hallways, or porches. Using this Smoke Alarm in
c
ommon areas may not provide sufficient warning to all residents or
m
eet local fire protection ordinances/regulations.
This Smoke Alarm alone is not a suitable substitute for complete fire
detection systems in places housing many people—like apartment
buildings, condominiums, hotels, motels, dormitories, hospitals, health
care facilities, nursing homes, day care facilities, or group homes of any
kind. It is not a suitable substitute for complete fire detection systems
in warehouses, industrial facilities, commercial buildings, and special-
purpose non-residential buildings which require special fire detection
and alarm systems. Depending on the building codes in your area, this
Smoke Alarm may be used to provide additional protection in these
facilities.
I
n new construction, most building codes require the use of AC or
A
C/DC powered Smoke Alarms only. In existing construction, AC,
A
C/DC, or DC powered Smoke Alarms can be used as specified by
l
ocal building codes. Refer to NFPA 72 (National Fire Alarm and
S
ignaling Code) and NFPA 101 (Life Safety Code), local building codes,
o
r consult your Fire Department for detailed fire protection requirements
i
n buildings not defined as “households”.
LIMITATIONS OF SMOKE ALARMS
S
moke Alarms have played a key role in reducing deaths resulting from
h
ome fires worldwide. However, like any warning device, Smoke Alarms
c
an only work if they are properly located, installed, and maintained,
a
nd if smoke reaches them. They are not foolproof.
Smoke alarms may not waken all individuals. Practice the escape
plan at least twice a year, making sure that everyone is involved – from
kids to grandparents. Allow children to master fire escape planning and
practice before holding a fire drill at night when they are sleeping.
If children or others do not readily waken to the sound of the smoke
alarm, or if there are infants or family members with mobility limitations,
make sure that someone is assigned to assist them in fire drill and in
the event of an emergency. It is recommended that you hold a fire drill
while family members are sleeping in order to determine their response
to the sound of the smoke alarm while sleeping and to determine
whether they may need assistance in the event of an emergency.
Smoke Alarms cannot work without power. Battery operated units
cannot work if the batteries are missing, disconnected or dead, if the
wrong type of batteries are used, or if the batteries are not installed
correctly. AC units cannot work if the AC power is cut off for any reason
(open fuse or circuit breaker, failure along a power line or at a power
station, electrical fire that burns the electrical wires, etc.). If you are
concerned about the limitations of battery or AC power, install both
types of units.
S
moke Alarms cannot detect fires if the smoke does not reach
t
hem. Smoke from fires in chimneys or walls, on roofs, or on the other
s
ide of closed doors may not reach the sensing chamber and set off the
a
larm. That is why one unit should be installed inside each bedroom or
s
leeping area—especially if bedroom or sleeping area doors are closed
a
t night—and in the hallway between them.
Smoke Alarms may not detect fire on another floor or area of the
home. For example, a stand-alone unit on the second floor may not
detect smoke from a basement fire until the fire spreads. This may not
give you enough time to escape safely. That is why recommended
minimum protection is at least one unit in every sleeping area, and every
bedroom on every level of your home. Even with a unit on every floor,
stand-alone units may not provide as much protection as interconnected
units, especially if the fire starts in a remote area. Some safety experts
recommend installing interconnected AC powered units with battery
back-up (see “About Smoke Alarms”) or professional fire detection
systems, so if one unit senses smoke, all units alarm. Interconnected
units may provide earlier warning than stand-alone units since all units
alarm when one detects smoke.
Smoke Alarms may not be heard. Though the alarm horn in this unit
meets or exceeds current standards, it may not be heard if: 1) the unit
is located outside a closed or partially closed door, 2) residents recently
consumed alcohol or drugs, 3) the alarm is drowned out by noise from
stereo, TV, traffic, air conditioner or other appliances, 4) residents are
hearing impaired or sound sleepers. Special purpose units, like those
with visual and audible alarms, should be installed for hearing impaired
residents.
Smoke Alarms may not have time to alarm before the fire itself
causes damage, injury, or death, since smoke from some fires may
not reach the unit immediately. Examples of this include persons
smoking in bed, children playing with matches, or fires caused by
violent explosions resulting from escaping gas.
Smoke Alarms are not foolproof. Like any electronic device, Smoke
Alarms are made of components that can wear out or fail at any time.
You must test the unit weekly to ensure your continued protection.
Smoke Alarms cannot prevent or extinguish fires. They are not a
substitute for property or life insurance.
Smoke Alarms have a limited life. The unit should be replaced
immediately if it is not operating properly. You should always replace a
Smoke Alarm after 10 years from date of purchase. Write the purchase
date on the space provided on back of unit.
First Alert
®
is a registered trademark of the First Alert Trust.
4 5
6
A
BOUT SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide protection even when
electricity fails, provided the batteries are fresh and correctly installed.
Units are easy to install, and do not require professional installation.
AC powered Smoke Alarms: Can be interconnected so if one unit
senses smoke, all units alarm. They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided
the batteries are fresh and correctly installed. AC and AC/DC units
must be installed by a qualified electrician.
S
moke Alarms for Solar or Wind Energy users and battery backup
p
ower systems: AC powered Smoke Alarms should only be operated
w
ith true or pure sine wave inverters. Operating this Smoke Alarm with
m
ost battery-powered UPS (uninterruptible power supply) products or
s
quare wave or “quasi sine wave” inverters will damage the Alarm.
I
f you are not sure about your inverter or UPS type, please consult with
t
he manufacturer to verify.
Smoke Alarms for the hearing impaired: Special purpose Smoke
Alarms should be installed for the hearing impaired. They include a
visual alarm and an audible alarm horn, and meet the requirements of
the Americans With Disabilities Act. Can be interconnected so if one
unit senses smoke, all units alarm.
Smoke alarms are not to be used with detector guards unless the
combination has been evaluated and found suitable for that purpose.
A
ll these Smoke Alarms are designed to provide early warning of fires if
l
ocated, installed and cared for as described in the user’s manual, and
i
f smoke reaches them. If you are unsure which type of Smoke Alarm
t
o install, refer to Chapter 2 of the National Fire Protection Association
(
NFPA) Standard 72 (National Fire Alarm and Signaling Code) and
N
FPA 101 (Life Safety Code). National Fire Protection Association,
O
ne Batterymarch Park, Quincy, MA 02269-9101. Local building codes
m
ay also require specific units in new construction or in different areas
o
f the home.
B
EDROOM
B
EDROOM
H
ALL
LIVING ROOM KITCHEN
F
INISHED BASEMENT
BEDROOM
B
EDROOM
L
IVING ROOM
DINING ROOM
M
ULTI-STORY RESIDENCE
S
INGLE-STORY RESIDENCE, APARTMENT,
M
OBILE HOME
EXISTING HOMES
K
ITCHEN
R
EQUIRED TO
M
EET NFPA
RECOMMENDATIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KEY:
SMOKE ALARMS WITH SILENCE
FEATURES RECOMMENDED FOR
ADDITIONAL PROTECTION
INTERCONNECTED
A
C OR AC/DC
S
MOKE ALARMS
BEDROOM
BEDROOM
H
ALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO
MEET NFPA
RECOMMENDATIONS
RECOMMENDED
F
OR ADDITIONAL
PROTECTION
B
EDROOM
BEDROOM
L
IVING ROOM
DINING ROOM
MULTI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
KEY:
NEW CONSTRUCTION
S
MOKE ALARMS
WITH SILENCE
FEATURES
R
ECOMMENDED
FOR ADDITIONAL
P
ROTECTION
KITCHEN
Printed in Mexico M08-0136-007 K1 12/12
WHAT TO DO IN CASE OF FIRE
Don’t panic; stay calm. Follow your family escape plan.
Get out of the house as quickly as possible. Don’t stop to get
dressed or collect anything.
Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly. Don’t open a hot door. Keep doors
and windows closed, unless you must escape through them.
Cover your nose and mouth with a cloth (preferably damp).
T
ake short, shallow breaths.
Meet at your planned meeting place outside your home,
and do a head count to make sure everybody got out safely.
Call the Fire Department as soon as possible from outside.
G
ive your address, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
A
larms have various limitations. See "Limitations of Smoke Alarms"
for details.
USING THE SILENCE FEATURE
T
he Silence Feature can temporarily quiet an unwanted alarm for up to
1
5 minutes. To use this feature, press the “Push to Test/Silence” button
o
n the cover. If the unit will not silence and no heavy smoke is
p
resent, or if it stays in silence mode continuously, it should be
r
eplaced immediately. The LED will flash every 10 seconds while in
s
ilence.
T
he Silence Feature does not disable the unit—it makes it temporarily
l
ess sensitive to smoke. For your safety, if smoke around the unit is
d
ense enough to suggest a potentially dangerous situation, the unit
w
ill stay in alarm or may re-alarm quickly. If you do not know the
s
ource of the smoke, do not assume it is an unwanted alarm. Not
r
esponding to an alarm can result in property loss, injury, or death.
TOOLS YOU WILL NEED:
This unit is designed to be mounted
on the ceiling, or on the wall if necessary.
• Pencil
• Drill with 3/16” (5 mm) drill bit
• Standard flathead screwdriver
Hammer
Pliers to activate optional “tamper-resistant”
l
ocking features
TO LOCK THE BATTERY COMPARTMENT
Do not lock the battery compartment until you have installed the
battery and tested the unit.
1
. Install the battery so the terminals
o
n the battery match the terminals
o
n the Smoke Alarm. Match “+” to
+” and “-” to “-.” Push the battery in
u
ntil it snaps in securely and cannot
b
e shaken loose. If the battery is
n
ot snapped in completely, the unit
c
annot receive battery power.
2. Push and hold Test/Silence button
until the alarm sounds: 3 beeps,
pause, 3 beeps, pause.
The Escape Light
®
will turn on.
LED flashes once every second.
I
f the unit does not alarm during
t
esting, DO NOT lock the battery
c
ompartment! Install a new battery
a
nd test again. If the Smoke Alarm still
d
oes not alarm, replace it immediately.
3. Using needle-nose pliers, detach
one locking pin from the mounting
bracket.
4. Push the locking pin through the
hole near the battery door latch on
the back of the Smoke Alarm.
OPTIONAL LOCKING FEATURES
TO LOCK THE MOUNTING BRACKET
1
. Using needle-nose pliers,
d
etach one locking pin from
the mounting bracket.
2. Insert the locking pin through
the hole on the back of the
Smoke Alarm as shown in the
diagram.
3. When you attach the Smoke
Alarm to the mounting bracket,
the locking pin’s head will fit
into a notch on the bracket.
The optional locking features are designed to prevent unauthorized removal of the battery or alarm. It is not necessary to activate the locks in
single-family households where unauthorized battery or alarm removal is not a concern.
T
hese Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the Smoke Alarm to the mounting
b
racket. You can choose to use either feature independently, or use them both.
T
ools you will need: Needle-nose pliers Standard flathead screwdriver.
Both locking features use locking pins, which are molded into the mounting bracket. Depending on which locking
features you use, remove one or both pins from the mounting bracket using needle-nose pliers.
To permanently remove either locking pin, insert a flathead screwdriver between the locking pin and the
lock, and pry the pin out of the lock.
TO UNLOCK THE BATTERY COMPARTMENT
1
. Remove the Smoke Alarm
f
rom the mounting bracket.
I
f the unit is locked to the
b
racket, see the section
To Unlock the Mounting
B
racket.”
2. Insert a flathead screwdriver
under the head of the locking
pin, and gently pry it out of the
battery compartment lock.
(If you plan to relock the battery
compartment, save the locking
pin.)
3
. To relock the battery compartment,
c
lose the battery door and reinsert
l
ocking pin in lock.
4
. Reattach the Smoke Alarm
t
o the mounting bracket.
When replacing the battery, always
test the Smoke Alarm before
relocking the battery compartment.
TO UNLOCK THE MOUNTING BRACKET
1. Insert a flathead screwdriver into
the rectangular cut-out on the
mounting bracket nearest to the
locking pin.
2. Pry the Smoke Alarm away from
the bracket by pushing up on
the screwdriver and turning the
Smoke Alarm counterclockwise
(left) at the same time.
NEVER use an open flame of any kind to test this unit. You might
accidentally damage or set fire to the unit or to your home.
The built-in test switch accurately tests the unit’s operation as
required by Underwriters Laboratories, Inc. (UL).
If the Alarm ever fails to test properly, replace it immediately.
Products under warranty may be returned to the manufacturer
for replacement. See “Limited Warranty” for details.
DO NOT stand close to the alarm when the horn is sounding.
Exposure at close range may be harmful to your hearing. When
testing, step away when horn starts sounding.
It is important to test this unit every week to make sure it is working
properly. Using the Test/Silence button is the recommended way to
test this Smoke Alarm. Press and hold the Test/Silence button on the
cover of the unit until the alarm sounds and the Escape Light
®
turns on
(the unit may continue to alarm for a few seconds after you release the
button). If it does not alarm, make sure the unit is receiving power and
test it again. If it still does not alarm, replace it immediately.
During testing you will hear a loud, repeating horn pattern: 3 beeps,
pause, 3 beeps, pause. The Escape Light
®
will turn on. LED flashes
once every second.
REGULAR MAINTENANCE
This unit has been designed to be as maintenance free as possible, but
there are a few simple things you must do to keep it working properly.
Test it at least once a week.
Clean the Smoke Alarm at least once a month; gently vacuum off
any dust using your household vacuum’s soft brush attachment,
and test the Smoke Alarm after cleaning. Never use water, cleaners
or solvents since they may damage the unit.
If the Smoke Alarm becomes contaminated by excessive dirt, dust
and/or grime, and cannot be cleaned to avoid unwanted alarms,
replace the unit immediately.
Relocate the unit if it sounds frequent unwanted alarms.
See “Locations to Avoid For Smoke Alarms” for details.
When the battery becomes weak, the Smoke Alarm unit will “chirp”
approximately once a minute (the low battery warning). This low
battery warning should last for up to 7 days, but you should replace
the battery immediately to continue your protection.
Choosing a replacement battery:
Your Smoke Alarm requires one standard 9V battery. The following
batteries are acceptable as replacements: Duracell #MN1604, (Ultra)
#MX1604; Eveready (Energizer) #522. You may also use a Lithium
battery like the Ultralife U9VL-J, U9VL-J-P for longer service life
between battery changes. These batteries are available at many
local retail stores.
Always use the exact batteries specified by this User’s Manual.
DO NOT use rechargeable batteries. Clean the battery contacts
and also those of the device prior to battery installation. Install
batteries correctly with regard to polarity (+ and -).
Please dispose of or recycle used batteries properly, following
any local regulations. Consult your local waste management
authority or recycling organization to find an electronics
recycling facility in your area. DO NOT DISPOSE OF BATTERIES
IN FIRE. BATTERIES MAY EXPLODE OR LEAK.
Keep battery out of reach of children. In the event a battery
is swallowed, immediately contact your poison control center,
your physician, or the National Battery Ingestion hotline at
202-625-3333 as serious injury may occur.
Actual service life depends on the Smoke Alarm and the environment
in which it is installed. All the batteries specified above are acceptable
replacement batteries for this unit. Regardless of the manufacturer’s
suggested battery life, you MUST replace the battery immediately once
the unit starts “chirping” (the “low battery warning”).
B
ATTERY POWERED PHOTOELECTRIC SMOKE ALARM
W
ITH SILENCE AND ESCAPE LIGHT
®
Model SA720
C
ONFORMS TO
UL STD 217
Model SA720
WEEKLY TESTING
LATCHING FEATURE
A
larm Latch is activated after an Alarm is exposed to alarm levels of
s
moke. After smoke drops below alarm levels, the Red LED will flash
3
times, spaced one second apart. The pattern repeats approximately
e
very 45 seconds unless reset by Test/Silence button. In addition,
i
nstead of waiting for up to 45 seconds to see if an alarm has had
t
he Alarm Latch feature set, a unit with an active Alarm Latch can be
i
dentified by pressing and holding (without releasing) the Test button.
I
f a unit has an active Alarm Latch, the Red light will blink rapidly (with
n
o horn sound) until the Test button is released. If the unit does not
h
ave an active Alarm Latch set, the unit will go through the normal test
c
ycle. Note: Once the Test button is released the Latching Feature will
b
e reset.
This feature helps emergency responders, investigators, or service
technicians identify which unit(s) in your home were exposed to alarm
levels of smoke. This can help investigators pinpoint the source of
smoke. The Alarm Latch stays ON until you clear it, so it can alert you
to an alarm that occurred while you were away from home, even
though smoke present in the air has dropped below alarm levels.
Vue de la page 0
1 2

Résumé du contenu

Page 1 - MOKE ALARMS

IMPORTANT! PLEASE READ CAREFULLY AND SAVE.This user’s manual contains important information about your SmokeAlarm’s operation. If you are installing t

Page 2 - DETECTOR DE HUMO Y FUEGO*

MANTENIMIENTO REGULARMANUAL DEL USUARIOImpreso en MéxicoM08-0136-007 K1 12/12INTRODUCCIÓNGracias por escoger a First Alert®para satisfacer su necesi

Commentaires sur ces manuels

Pas de commentaire